Description
INSTRUCTIONS FOR USE
WARNING : This water filter, as well as all OLYMPUS + water filters, are intended for connection to water supply networks controlled by municipal authorities and supplying water suitable for human consumption.
Before installation and use, read these instructions carefully.
Install the system correctly according to the instructions and keep this manual for future reference.
REVERSE OSMOSIS



REVERSE OSMOSIS SYSTEM (R/O) USER INSTRUCTIONS
1. Product features
The R/OLYMPUS + device passes water through 4 purification stages, and each of the 4 filters it has fulfills its role effectively, so as to retain harmful substances, microorganisms carried in the water, colloids, organic materials, heavy metals, particulate sludge sediments, nitrates, etc.
Also, the third stage, the reverse osmosis membrane, is the main filter that transforms hard water into soft water by retaining calcium and magnesium salts, as well as salt from brackish water, so that unsuitable water becomes normal drinking water.
2. Brief instructions for the water filtration module and its operation.
Stage 1: Polypropylene cartridge (filter).
The polypropylene cartridge retains sediment, colloids, rust and sludge deposits present in the water.
Stage 2: Compact cartridge reinforced with activated carbon that retains: chlorine, pesticides, asbestos, heavy metals, chemical elements, while improving the taste and smell of water.
Stage 3 : Reverse osmosis filter.
The principle of the reverse osmosis cartridge is to remove microscopic contaminants, calcium and magnesium salts, nitrates, brackish water salt, colloids, heavy metals, stable soluble substances, microbes and other harmful elements from water.
Stage 4: Activated carbon filter.
This is the last filter that refreshes the water stored in the tank the moment we open the tap to use the stored water.
3. DIAGRAM – WATER TREATMENT – COMPONENTS – CONNECTION METHOD

1. Water connection fitting.
2. Switch
3. Pre-filter for solid particles
4. Compact activated carbon filter
5. Water flow distributor and automatic switch.
6. R/O membrane chamber
7. Wastewater drain pipe
8. Tank switch
9. Water tank with pressure pump
10. Activated carbon filter
11. Faucet
12. Plastic connecting pipe
13. Blue membrane flush switch
HOW TO CONNECT THE PIPES TO THE UNIT:

A) Connection point for mains water supply (red plug)
B) Connection point for the device tank (yellow plug)
C) Connection point for tap (blue plug)
– Rear plug: connection point for the sink drain pipe, for draining waste water (black plug)
REVERSE OSMOSIS SYSTEM (R/O) USER INSTRUCTIONS
4. Important technical parameters
Pure water flow rate: 150-180L/24 hours (50GPD) (25 °C) and, depending on the water pressure, the tank fills in approximately 3 to 5 hours.
Adequate water source pressure: 3 – 7 BAR
Permissible ambient temperature: 5–40 °C
5. Installation
The RO system should be installed according to the conditions in your kitchen (see image 1).
The most correct installation of the appliance is in a cabinet under the kitchen counter (image 1). In special cases, it can also be installed above the kitchen counter or even on the wall.
For the correct connection of the appliance to the water mains, refer to the diagram on page 3. Also, for the correct connection of the white plastic tube to the filter sockets and the tap, refer to diagram 4 on page 4.

HOW TO CONNECT THE TUBE TO THE FILTER CONNECTORS AND THE TAP
To remove the colored plugs (blue, yellow, red and black): First remove the blue safety clip. Then, press inwards on the white plastic ring on which the blue clip is placed and pull the plug out. To connect the tube, simply push it into the connector socket where the blue clip is located, then put the blue clip back in place. To disconnect the plastic tube, turn off the water supply and follow the same procedure as for removing the colored plugs.
REVERSE OSMOSIS SYSTEM (R/O) USER INSTRUCTIONS
Installing the faucet
The most correct position for the faucet is to install it on the kitchen sink.
Installing the reverse osmosis membrane: After disconnecting the tube from the chamber cover, unscrew the plastic cover of the reverse osmosis chamber. Apply pharmaceutical Vaseline to the front of the reverse osmosis membrane, where the two rubber O-rings are located. Then, insert the cartridge into the reverse osmosis chamber and, after pressing it firmly to insert it well into the socket at the bottom of the chamber, screw the reverse osmosis chamber cover tightly. In case of replacing the R/O cartridge, after disconnecting the tube, unscrew the chamber cover and with a tool (pliers or wrench) firmly pull the back of the cartridge to remove it. Then, insert the new cartridge, after previously applying pharmaceutical Vaseline to the front.
6. Use – Washing the filters
When using the reverse osmosis (R/O) machine for the first time or when replacing the activated carbon or membrane filters, empty the water tank once or twice, as the first water is intended for washing the filters and not for use. After this filter cleaning procedure, the water produced by the machine and stored in the tank is suitable for any use. When the tank is full, the system will automatically stop operating.
NOTE : Every 3-4 months or sooner if necessary, you can wash the membrane (6) for 5-10 minutes by opening the blue switch (13) located at the back of the appliance, on the drain pipe.
VERY IMPORTANT:
Reverse osmosis separates the problematic water from the clean water and sends approximately 80-85% to the sewer as unusable, while the clean water is stored in the water tank (9), which, depending on the network pressure, is filled with clean water within 3 to 5 hours, and the system stops until we use a certain amount of water, at which point it will automatically start working to refill the tank.
7. Maintenance
Change the cartridges regularly, according to the instructions, to always have the best water quality.
If the cartridges are changed regularly, reverse osmosis device users can enjoy clean water of the highest quality. The following instructions indicate the filter replacement periods and should be followed:
Stage 1 filter (sediment pre-filter) from 3 to 6 months.
Stage 2 filter (compact activated carbon) from 9 to 12 months.
3rd stage filter (reverse osmosis membrane) from 12 to 18 months.
4th stage filter (activated carbon) from 9 to 12 months.
The replacement period for each cartridge also depends on the degree of water pollution in each area with pollutants, salts, nitrates, etc., as well as the amount of clean water consumed. Therefore, if you follow the recommended filter replacement periods listed above, the R/O system can guarantee you good water quality and purity.
REVERSE OSMOSIS SYSTEM (R/O) USER INSTRUCTIONS
8. CAUTION
1. Due to the different pressures in the network from one installation to another, the manufacturer recommends installing a pressure reducer and an anti-shock valve (available in plumbing stores) before the water filter, so that in the event of an increase in network pressure or a momentary water hammer phenomenon, the pipes or the filter unit do not burst and cause flooding. When leaving home for several days, close the filter supply valve.
2. Please do not disassemble the machine components in case of a leak or damage to it, as you may cause a flood.
3. The tank at its bottom has an air valve and you should never remove or increase the air pressure present in the tank, as the water pump will not work.
4. If the system is not used for a long time, you should close the R/O switch located immediately after connecting to the home water supply. The same applies when you are away from home for several days.
5. If the R/O unit is taken out of service for a long time, when it is used again, you must follow the operating instructions as for the first time use.
6. Careful handling is required during transportation and installation.

CENTER PLUS SA
● ACHARNES: L. Karamanli 87 (13679) Tel. 210.2405900 Fax 210.2405583
● ATHENS: Veranzerou 40 (10432) Tel. 210.5230440 Fax 210.5233388
TWO (2) YEAR WARRANTY
This warranty is valid for 2 years and:
a) Obliges the company CENTER PLUS SA to remedy, free of charge, any damage or functional problem of the water filter OLYMPUS + DRINKING WATER FILTERING SYSTEM WITH REVERSE OSMOSIS.
b) Obliges the user of the filter, at his own risk and expense, to deliver or send the device presenting the problem for inspection and repair to the company's service center, at the address Leof. Karamanli 87, (13679), Acharnes – Attica. Tel. 210-2405900
ATTENTION: THIS WARRANTY DOES NOT COVER:
1) Broken parts and components of the device or cartridges (due to improper use).
2) Clogged replacement cartridges due to lack of user maintenance or a high load of salts, rust and sludge in the water.
3) Rupture of the housings that enclose the filters or the connecting pipes due to excessive pressure in your network or due to the water hammer phenomenon, in which the pressure in the network momentarily increases uncontrollably, if you have not installed an anti-shock valve in your home network, which we recommend for your safety.
4) The faucet that does not seal and has a leakage problem due to the accumulation of salts or sludge, after 6 months.
5) Intervention by an unauthorized technician.
6) The responsibility for the correct and safe installation of the filter lies with the customer.
View the product instructions in PDF format by clicking here.